Test ID BLOD1558 HIV-1/HIV-2 RNA Detection, Plasma
Specimen Type/Requirements
Lavender top (EDTA) tube - Plasma
Specimen should be centrifuged and separated within 2 hours of collection.
Test may be affected by gross hemolysis.
Specimen Volume
Specimen Volume
| Preferred Volume | 1.5 mL |
|---|---|
| Minimum Volume | 0.75 mL |
Stability/Transport
| Room Temperature | 1 day | |
|---|---|---|
| Refrigerated | 5 days | |
| Frozen | 6 weeks | Preferred for transport |
Performed Test Frequency
Monday, Wednesday, Friday
Report Available
48 hours
Performing Lab
Sanford Laboratories Sioux Falls
CPT
87538, 87535
Interface Build Information
SANFORD LABORATORIES INTERFACE BUILD INFORMATION
| Result Code | Result Code Description |
|---|---|
| 29279 | HIV-1 RNA |
| 29280 | HIV-2 RNA |
Additional Information
Due to the potential cross-reactivity between some NAT assays and certain lentiviral vector-based CAR-T cell therapies, clinicians should exercise caution when ordering and interpreting HIV testing in patients who have received CAR-T cell therapy. Some lentiviral CAR-T vectors contain a target region of the test, which can lead to false positive HIV-1 results.