Test ID BLOD0671 Sickle Cell Screen
Specimen Type/Requirements
Lavender top (EDTA) tube - Whole Blood
Pediatric minimum – 1 full EDTA microtainer.
Positives should be followed by Hemoglobin Electrophoresis.
NOTE: This assay is not appropriate for children under 6 months of age.
Test is not affected by hemolysis or lipemia.
Specimen Volume
| Preferred Volume | 4.0 mL |
|---|---|
| Minimum Volume | 1.0 mL |
Stability/Transport
| Room Temperature | Not Acceptable | |
|---|---|---|
| Refrigerated | 7 days | Preferred for transport |
| Frozen | Not Acceptable |
Performed Test Frequency
Monday through Sunday
Specimens are batch tested within 7 days from collection.
STAT testing available upon request.
Methodology
Solubility
CPT
85660
Performing Lab
Sanford Laboratories Sioux Falls
Interface Build Information
| Result Code | Result Code Description |
|---|---|
| 3685 | Sickle Cell Screen |