Test ID BLOD1574 CMV T Cell Immunity Panel
Specimen Type/Requirements
Dark Green Top (Sodium Heparin w/out Gel) - Whole Blood
Drawn Monday through Friday - never prior to a holiday -
and arrive at Sanford Laboratories Send Out Department prior to 3:00 pm.
Must be received at the performing lab within 32 hours of collection.
NOTE: Tubes must be at least 3/4 full to maintain proper ratio of blood to anticoagulant.
Stability/Transport
Room Temperature | 32 Hours | Preferred for Transport |
---|---|---|
Refrigerated | Not Acceptable | |
Frozen | Not Acceptable |
Methodology
Flow Cytometry after Stimulation
Performing Lab
Viracor Eurofins
CPT
86352 x 4
Specimen Volume
Preferred Volume | 10.0 mL |
---|---|
Minimum Volume | 5.0 mL |
Performed Test Frequency
Monday through Friday
Additional Information
The CMV T Cell Immunity Panel measures the strength of T cell responses to Cytomegalovirus (CMV) specific antigens. It evaluates and reports the activity of CD4 and CD8 T cell responses independently. Effective T cell immunity against CMV is a factor in controlling CMV viral latency. CMV can affect patients with weakened immune systems and is a common risk factor in patients following solid organ or hematopoietic stem cell transplant.
Report Available
2-3 days
Interface Build Information
Result Code | Result Description |
---|---|
23767 | % CD4 CMV Interferon-Gamma Cells |
23768 | % CD8 CMV Interferon-Gamma Cells |
23769 | % CD4 SEB Interferon-Gamma Cells |
23770 | % CD8 SEB Interferon-Gamma Cells |
23771 | Viability |